4.2
Termination
VIVISUN Compact bodies require a specially keyed solderless Connector Plug (P/N 18-442). Plugs can be ordered with VIVISUN Compact bodies or ordered separately. An Extraction Tool (P/N 18-234) is required to remove the Connector Plug from the VIVISUN Compact body. The Connector Plug can be inserted into the VIVISUN Compact body before or after installation. Please note, this connector plug is different than the plug required for switch/indicator bodies that do not contain any NEXSYS components.
Figure 4.2.0.0-A |
||
---|---|---|
Pins | Compact Body | Connector Plug |
A-G | Illumination Circuits |
![]() P/N 18-442 |
A1-A4, B1-B4 | NEXSYS Component or switch Contacts |
Connector Plug designed to accept 20, 22, or 24 gauge wire terminated with MIL-C-39029/22-192 (P/N 18-219) crimp sockets. Wires with the sockets crimped on can be inserted into and extracted from the Connector Plug using a M81969/14-02 (P/N 18-216) extraction tool.
VIVISUN High Capacity bodies require a specially keyed solderless Connector Plug (P/N 18-440). Plugs can be ordered with VIVISUN High Capacity bodies or ordered separately. An Extraction Tool (P/N 18-234) is required to remove the Connector Plug from the VIVISUN High Capacity body. The Connector Plug can be inserted into the VIVISUN High Capacity body before or after installation. Please note, this connector plug is different than the plug required for switch/indicator bodies that do not contain any NEXSYS components.
Figure 4.2.0.0-B |
||
---|---|---|
Pins | High Capacity Body | Connector Plug |
A-G | Illumination Circuits |
![]() P/N 18-440 |
H1-H4, L1-L4, J1-J4, K1-K4 |
NEXSYS Component |
Connector Plug designed to accept 20, 22, or 24 gauge wire terminated with MIL-C-39029/22-192 (P/N 18-219) crimp sockets. Wires with the sockets crimped on can be inserted into and extracted from the Connector Plug using a M81969/14-02 (P/N 18-216) extraction tool.